Generic information, Doubler enclosure capacities with full solar load, Eneric – ADC and 3 Doubler User Manual

Page 15: Nformation

Advertising
background image

LTPH-UM-1234-01

Generic

Information

HDU-409 Lists 1, 2, and 3

April 30, 2003

9

G

ENERIC

I

NFORMATION

This section provides generic information for both the HiGain and PG-Flex
applications.

D

OUBLER

E

NCLOSURE

C

APACITIES

WITH

F

ULL

S

OLAR

L

OAD

The physical location of the doublers is driven by the following three
deployment rules:

1

Place the enclosures at the electrical limits (35 dB) of each span. This
places the first doubler at the 35 dB location and the second at 70 dB and
so on. This allows the maximum circuit range to be realized.

2

If Rule 1 is not applicable, try to make all spans the same electrical length
(same 196 kHz loss). This minimizes the maximum span loss and assures
maximum operating margin, resulting in optimal transmission
performance on the HDSL cable pairs. If specific application constraints
preclude using rule 2 or, if two different circuit layout choices have the
same maximum span loss, then use Rule 3.

Caution must be observed when pushing doubler spans to
their 35 dB maximum range. Refer to ADC’s Technical
Advisory #TA-015 on HiGain operating ranges and general
deployment guidelines.

Advertising
This manual is related to the following products: