Heating- quick start & stop, Getting started – Aquacal 110 User Manual

Page 10

Advertising
background image

10

HEATING- QUICK START & STOP

Getting Started

(Quick-Start & Stop Continued Next Page)

1. Verify Electrical Power is Present at Heater:

A. Ensure that the unit has electrical power connected; the heater controller display should be

illuminated.

B. If the display is blank, be certain the electrical breaker, and heater disconnect, are switched to

“ON.”

C. For now, leave the water circulation pump OFF.

A. The user/owner settings can be made without water flowing. Once the heater has electrical

power connected, with water not flowing, the display should read FLO.

B. Press the MODE button until the HEAT (HEA) indication displays. This action will enable the

remaining programming keys.

C. Using the POOL / SPA selector key, select the POOL mode. An illuminated POOL indicator

light, located on the left side of the display, will confirm the POOL control has been selected.
If heating only a spa, using the DOWN arrow key, lower the POOL temperature until OFF is
displayed; then proceed to Step-“E.”

D. Use the UP / DOWN arrow keys to set the desired water temperature for the POOL water.

E. If the heat pump will be used to heat a spa, use the POOL/SPA selector key to select SPA,

then use the UP / DOWN arrow keys to set the desired water temperature for the SPA. An
illuminated SPA indicator light, located on the left side of the display, will confirm the SPA
control has been selected. If heating only a POOL, using the DOWN arrow key, lower the
SPA temperature until OFF is displayed.

F. The heat pump controls are now set to maintain the desired water temperature for the POOL

and/or SPA.

2. Set the Heater Controls (Refer to Control Panel Layout, Pg-12):

OWNER- If heater is connected to a Call-Flex controller, also see “Selecting Call-Flex Pump
Options,” located on page-17 of this manual.

INSTALLER- Is heater connected to an external controller? If so, see external controller
information located on pages 41 and 44 of this manual.

This brief information is provided as an aide to installers, service personnel, and owners. The intent of
this section is to provide rapid access to very basic operational information. Individuals who will be
routinely using, installing, maintaining, and servicing this heat pump, are strongly encouraged to read
this entire manual. Herein, the terms: Heat Pump, Heater, and Unit are used synonymously. These
instructions are intended for local control of a heat pump, independent of an external con-
troller. Owners: if your installation includes an external controller, contact your installing dealer,
or the external controller manufacturer, for external controller operating instructions.

These instructions are for quick-starting in the HEATING mode... Owners of Heat-Cool units, in
order to utilize all features of their heater, will certainly want to also refer to: Owner Level Program-
ming, beginning on page-14 of this manual.

Advertising
This manual is related to the following products:

100, 101, 135, 120, 121, 156, 155, 111