Location Requirements . . .

Select a location with a solid floor.

No other fuel burning appliance should be installed in
the same closet with the dryer.

The dryer must not be installed or stored in an area
where it will be exposed to water and/or weather.

Leveling legs can be adjusted from inside the dryer
with a 1/4" driver. All four legs must rest firmly on the

floor so the weight of the dryer is evenly distributed.
The dryer must not rock.

The dryer needs sufficient clearance and an adequate
air supply for proper operation and ventilation, and for
easier installation and servicing. (Minimum clearances
are shown below.)

CLOSET

DOOR

D317IE3C

FRONT VIEW

(w/o Closet Door)

SIDE VIEW

A

A

C

A

D

E

B

CENTERED

AIR

OPENINGS (G)

(2 Openings

Minimum)

FRONT VIEW

(Closet Door)

F

F

OUTER

WALL OF

ENCLOSURE

**42"

** NOTE: For new installations, locate top of wall vent 42 inches above floor to make venting easier to

connect.

AREA

DESCRIPTION

FREE STANDING / ALCOVE
INSTALLATION
(See Illustration)

CLOSET INSTALLATION
(See Illustration)

A

Dryer sides and rear clearance

0" (0 cm)

0" (0 cm)

B

Dryer top clearance

12" (30.5 cm)

12" (30.5 cm)

C

Dryer front clearance

Not Applicable

2" (5.1 cm)

D

Exhaust duct clearance to
combustible material

2" (5.1 cm)

2" (5.1 cm)

E

Weather hood to ground clearance

12" (30.5 cm)

12" (30.5 cm)

F

Distance from floor or ceiling to
hole edge

Not Applicable

3" (7.6 cm)

G*

Area of centered air openings in
closet door

Not Applicable

40 sq. in./open (260 sq. cm)

*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)