Variety steamer, 400f, Programming – Antunes, AJ VS-350 User Manual

Page 12: General programming, Factory settings, Programming the unit

Advertising
background image

Variety Steamer

12

P/N 1010745 Rev. g 03/06

General programming

cYc (total cycle time) refers to the total amount of

cooking time set for the product (figure 4).

rate (shot Interval time) is the time set between

each shot of steam during a complete cycle (figure 5).

prOGrammInG

UP

DOWN

PROGRAM

START/STOP

400F

to verify or change the generator setpoint tempera-

ture, press and hold the uP and DOWN arrow buttons

simultaneously for three seconds. then, raise or lower

the temperature by depressing the uP or DOWN arrow

buttons. Release the buttons when the desired tem-

perature is reached.

UP

DOWN

PROGRAM

START/STOP

15:00

to change the display from fahrenheit (f) to celsius

(c), press and hold the uP arrow and the PROgRaM

buttons simultaneously for three seconds. Repeat the

process to reverse.

UP

DOWN

PROGRAM

START/STOP

15:00

to verify the actual generator temperature, press and

hold the uP arrow button. the unit will display the

actual generator temperature.

before starting initial programming, there are three

items that should be verified.

* check/change the setpoint temperature of the gen-

erator (it is recommended that the generator be set

at 375°f (191°c).

* change the display from fahrenheit (f) to celsius

(c) or vice versa.

* Verify the generator temperature after a 30 minute

pre-heat time.

Listed below are the steps to follow for the recommen-

dations listed above.

sHOt (steam shot time) is used to adjust the water

volume used during each solenoid operation (shot of

steam) (figure 6).

the amount of steam produced by your unit depends

on the amount of water sprayed onto the steam genera-

tor surface. flooding of the generator may occur if the

sHOt setting is too high or if the Rate setting is too

low.

to prevent this from occurring, the Rate (shot interval

time) should be increased to allow more time for gen-

erator heat recovery, and the sHOt (steam shot time)

can be decreased to reduce the water volume.

adjustments should be made to both values to deter-

mine the optimum settings for your cooking needs.

factory settings

the Vs-350 is factory programmed for the following val-

ues for each of the 4 menu channels:
cYc = [00:10] 10 seconds

(Range: 1 second to 99 minutes 59 seconds)

rate = [00:05] 5 seconds (recommended)

(Range: 1 second to 5 minutes 59 seconds)

sHOt = [00:70] 0.70 seconds (recommended)

(Range: 0.10 second to 2.50 seconds)

these settings deliver approximately 3/4 oz. (25 millili-

ters) of water every 5 seconds for a 10 second cooking

time. changes may be made to any of these settings.

However, for optimum performance, settings should

remain as shown above.

to restore the factory settings:

1. turn the unit off.

press and hold the Program

and single shot buttons.

2. turn the unit on while still holding these buttons.
3. Release the buttons as soon as the unit stops

beeping.

programming the Unit

nOte: cYc, rate, and sHOt are sequential opera-

tions per channel for all programming (you must

perform all steps for cYc and rate to change

sHOt).

nOte: cYc, rate, and sHOt are only displayed

momentarily during the programming sequence
when the prOGram button is pressed.