Variety steamer, Shot, Open – Antunes, AJ VS-350 User Manual

Page 17: Temp

Advertising
background image

17

Variety Steamer

P/N 1010745 Rev. g 03/06

UP

DOWN

PROGRAM SINGLE SHOT

1

2

3

4

SHOT

pwr (Power) will be displayed when the supply volt-

age is lower than 160 Volts ac or above 265 Volts ac.

PWR

UP

DOWN

PROGRAM SINGLE SHOT

1

2

3

4

SHOT

Open will be displayed when the thermocouple is “open” or not

installed correctly. the unit will not call for heat.

OPEN

UP

DOWN

PROGRAM SINGLE SHOT

1

2

3

4

SHOT

temp indicates the control cabinet temperature has exceed-

ed 155°f (68°c) causing the unit to shut down.
the teMP Display indicates that the control cabinet tem-

perature has exeeded 155°f (68°c). if this occurs, the unit

must be turned off for at least 20 minutes so that it can cool

off and reset. if this condition occurs again, contact your

maintenance person or authorized service agency.
the control board monitors the control cabinet ambient

temperature and records the highest temperature. Your ser-

vice technician could find such information very useful when

troubleshooting the unit.
to determine the control cabinet’s highest temerature since

the last reset:
1. turn the unit Off.

2. turn the unit back ON while pressing both the uP and

DOWN arrow buttons at the same time.

3. Read the highest control cabinet temperature recorded

on the display and release the arrow buttons.

4. turn the unit Off again to preserve this record.

to clear/reset this record, press both the uP and DOWN

arrow buttons simultaneously (before turning the unit Off)

and the display will show 33°f - indicating that record has

been cleared - and then turn the unit Off.

TEMP

UP

DOWN

PROGRAM SINGLE SHOT

1

2

3

4

SHOT

lOw will be displayed until the generator temperature exceeds

250°f (121°c).

LOW

UP

DOWN

PROGRAM SINGLE SHOT

1

2

3

4

ERR

err (error) will be displayed if there is a programming

parameters error. if this message appears you will have to

clear the current parameters.
to clear the unit’s current programming and reset the unit to

its factory settings:
1. turn the unit off.

2. Push the single shot and Program buttons simultane-

ously and, while turning the unit back on, continue to

hold them until you hear the beep stop.

3. check the display:

• if the Display shows “eRR” again, repeat steps 1

through 2. if “eRR” still appears on the display,

contact your maintenance person or authorized

service agency.

• if the Display appears normal, try a single shot

before attempting to reprogram the unit.

Review the Programming section of this manual and then

program the Menu channel buttons according to your cook-

ing requirements.