Section 4: maintenance, Replace the fuse, General troubleshooting – Avenview SW-DVI-16X16 User Manual

Page 27: 1 replace the fuse, 2 general troubleshooting

Advertising
background image

www.avenview.com

27

Section 4: Maintenance

4.1 Replace the Fuse

There is a spare fuse hidden in the power socket. Pull out the power cord and open the place showed on the
picture, then pull out the fuse socket and put in a new fuse.








4.2 General Troubleshooting

Problem

Reason

Possible Solution

Power LED is not ON

No power connected

Fuse is melted down

Power cord is short circuit

Ensure that power cable is
connected

Replace the fuse

No Signal Input and IN LED is ON

The cable of Input is short
circuit or completely off

The prior equipment doesn’t
Output signals

The prior equipment is PC
which has never been
disconnected

Check or change the cable of
Input

Ensure that equipments have
signal by operating them

Change the PC’s resolution

No Signal Output and IN LED is ON

The cable of output is not
connected

The device is not outputting
signal

Check the cable of output

Ensure that device is
outputting the signal

There is a signal output with wrong
colors and EDID LED is blinking

The resolution from the
source is not supported by
the Matrix Switch

Set the supported resolution
on source device (PC etc) and
then restart the source
device

When setting high resolution,
either there is no signal or output
signal is not correct

DVI cable is not of good
quality

DVI cable is over 5 meters

Use high performance DVI
cable

Ensure that cable length
between the source and DVI
Matrix switch is less than 5
meters

For safety consideration, please cut off the power supply before replacing the new fusee.

Advertising