Ii. system components, Front cooling fan control board, Message led description – Asus Dual Pentium II Department Server AP2500 User Manual

Page 18

Advertising
background image

18

AP2500 Hardware Reference Guide

II. Components

Front Cooling Fan Control Board

The front cooling fans’ main purpose is to cool the hard disk drives. These
fans also have a fan control board like the rear cooling fans. The front cool-
ing fan module consists of a control board, a hard disk drive LED status
board, and two cooling fans. The message LED board mounted in the front
of the cooling fan module consists of five sets of LEDs to represent the
status of up to five hard disk drives. Each set has three LEDs which shows
the power, activity, and status of each hard disk drive.

II. System Components

LED Board Header
(For cable to connect to

fan board)

Hard drive Power LED (Green)

Hard drive Access LED (Yellow)

Hard drive Status LED (Red)

Hard disk drive message board

pin 1

3-pin Fan Header

Gold Finger
Connector to the

SCSI Back plane
Board

LED Board Header
(For cable to connect to

LED board)

Front cooling fan control board

pin 1

Power LED

Status LED Description

off

off

power subsystem OK and ready for hard drive insertion

on

off

Hard disk drive is OK for operation

on

on

Hard disk drive failure (*)

on

fast flash

RAID in rebuilding (*)

on

slow flash

Hot-spare hard disk drive (*)

fast flash

on

Hard disk drive power failure/short circuit

fast flash

fast flash

Fan failure

Message LED Description

* Must be provided by RAID controller’s SAF-TE function.