Ii. system components, Scsi id setting – Asus Dual Pentium II Department Server AP2500 User Manual

Page 25

Advertising
background image

AP2500 Hardware Reference Guide

25

II. Components

II. System Components

SCSI ID Setting

SCSI ID settings are made through DIP switches located on the SCSI board.
The SCSI board has four dip switches to set the hard drive’s power on delay
and SCSI ID.

SCSI ID Setting

RMT_START DLY_START description
off

off

Motor up when power on

on

off

Motor up after START UNIT command

off

on

Motor up after 12xSCSI ID ms

on

on

Reserved

IDSEL1 IDSEL0 Slot1

Slot2

Slot3A/3B

Slot4

Slot5A/5B

off

off

Reserved

on

on

15

12

11

8

3

on

off

14

9

6

4

1

off

on

13

10

5

2

0

Hard Disk Drive Power On Delay

1” Tray
Connector #5

1” Tray
Connector #4

1” Tray
Connector #3

1” Tray

Connector #2

1” Tray
Connector #1

1.6” Tray

Connector #5B

1.6” Tray

Connector #3B

1.6” Tray

Connector #1

Advertising