Basic Switch Management

74

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Once the Hexadecimal is converted into a binary bit map, each bit represents a
port, where a value of 1 means yes and a value of 0 means no. The bit map is read
from right to left, that is, the least significant bit represents port 0.

For example, if the member port value is displayed in hex as:

0x00012083

This corresponds to a binary bit map of the member ports as follows:

0000 0000 0000 0001 0010 0000 1000 0011

This bit map displays the member ports as port 0, 1, 7, 13, and 16. Note that each
switch has an internal port (in the example above, port 16) which is always a
member of a broadcast group.

5 = 0101

D = 1101

6 = 0110

E = 1110

7 = 0111

F = 1111

Table 4: Hexidecimal to binary conversions (Continued)

Hex value = Binary value

Hex value = Binary value

Advertising