Appendix e - the i/o terminal block connector – axis international marketing 2130R PTZ User Manual

Page 34

Advertising
background image

The I/O Terminal Block Connector

AXIS 2130/2130R User’s Manual

34

Appendix E - The I/O Terminal Block Connector

A 4-pole connector is provided for external I/O connections to the AXIS 2130/2130R. The

connector provides the interface to a single output and a single input. A diagram for the

connector, complete with a pinout table is provided below.

Input

Used for connecting external alarm devices and triggering images for specific alarm-based

events, the input is typically connected to a motion detector - or any other external

security device - for saving images on each occasion the detector is activated.

Output

The output can drive a maximum load of 50V DC at 100mA directly, and by connecting

additional relay circuitry, it can drive even heavier loads. If the output is used with an

external relay, a diode must be connected in parallel with the load for protection against

any voltage transients.

Pins

Function

OUT A
OUT B

The two external device output terminals (A and B) are automatically switched to the
connected or disconnected postion - there is no distinction between + and -. The terminals
use optocouplers and are electrically insulated from the other internal circuitry.
The maximum load should not exceed 100mA and the maximum voltage should be no
higher than 50V DC.

Note: Connecting AC to the output will damage the unit.

IN+
IN -

The external device input terminals consist of a + terminal and a - teminal. The - terminal is
grounded on the inside of the main unit. Interupts are generated by connecting cables to
the terminals and shorting (ON) or breaking (OFF) the circuit. Sensors and switches should
be connected to these terminals with electrically isolated GND and power supplies.