HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 194

Advertising
background image

Virtual Connect modules 194

Port Statistic

Description

IfHCOutMulticastPkts

The total number of packets that higher-level protocols requested be

transmitted, and which were addressed to a multicast address at this

sublayer, including those that were discarded or not sent. For a MAC

layer protocol, this includes both Group and Functional addresses. This
object is a 64-bit version of ifOutMulticastPkts.

IfHCOutBroadcastPckts

The total number of packets that higher-level protocols requested be

transmitted, and which were addressed to a broadcast address at this
sublayer, including those that were discarded or not sent. This object is a

64-bit version of ifOutBroadcastPkts.

Remote Device Information

Description

remote_type

Type of remote device. Virtual Connect uses this information to configure

the link as an uplink, a stacking link, or to disable. This information is

based on the LLDP data sent by the device to which the port is attached.

remote_discovered_time

Time the remote device was identified, represented in seconds. This
information is based on the LLDP data sent by the device to which the port

is attached.

remote_chassis_id_type

Chassis ID subtype of the remote device.

remote_chassis_id

Chassis ID value of the remote device.

remote_port_id_type

Port ID subtype of the remote device.

remote_port_id

Port ID value of the remote device.

remote_port_desc

Port description of the remote device.

remote_system_name

System name of the remote device. If the remote device is a VC-Enet

module, remote_system_name is the remote device's VC domain name.

remote_system_desc

Description of the remote system. If the remote device is a VC-Enet module,

remote_system_desc is the module's hardware description and firmware
revision.

remote_system_capabilities

System capabilities of the remote system, for example, repeater, bridge,

or router.

remote_mgmt_addr_type

Management address subtype of the remote device, for example, IPv4,
IPv6, or DNS.

remote_mgmt_addr

Management address of the remote device.

Pluggable Module Information

Description

identifier

Identifies the type of serial transceiver. The binary values are defined in

SFF-8472 in the Identifier [Address A0h, Byte 0] field. This field displays

an ASCII representation of those binary values.

ext-identifier

Extended identifier for the type of serial transceiver. The values are
defined in SFF-8472 in the Extended Identifier [Address A0h, Byte 1]

field.

connector

Connector type of the serial transceiver. The binary values are defined in

SFF-8472 in the Connector [Address A0h, Byte 2] field. This field displays
an ASCII representation of those binary values, such as “RJ45”.

vendor-name

Name of the manufacturer (not HP). This is defined in SFF-8472 in the SFP

Vendor Name [Address A0h, Bytes 20-35] field.

vendor-oui

IEEE company ID of the manufacturer (not HP). This is defined in SFF-8472
in the Vendor OUI [Address A0h, Bytes 37-39] field.

Advertising