HP StorageWorks XP Remote Web Console Software User Manual

Page 58

Advertising
background image

58

External Storage XP for the XP10000/XP12000

Product
The external disk array product name

Serial
The external disk array serial number

Group
The external LU group and reference number

Characteristic
Identification number of external LU.

Device
The external LU device type

Capacity
Capacity of external LU

Alternate Path List
Status of alternate paths. The Alternate Path list consists of two tables. The Configured Paths table

displays previously defined paths. The Available Paths table displays available paths. The Alternate

Path list displays the following information:
• Port: The local disk array port number
• WWN: Identification number of the external disk array port.
• LUN: The external LU number.
• Priority: Priority of paths connecting to external LU. A 1 indicates the path with the highest priority.
• Status: Status of path to external LU. For information on reacting to status displayed, see

Troubleshooting External Storage XP

” on page 74. Possible values:

• Normal: Path status is normal
• Unknown: Path status is unknown.
• Blockade: I/O traffic is blocked.
• External device setting changed: Something about the external disk array has changed. For

example, a path definition was deleted or the external disk array was replaced.

• LDEV size reduced: The volume capacity of the external disk array has changed (volume

capacity was reduced)

• Not ready: The external disk array replied NOTREADY.
• Illegal request: The external disk array replied ILLEGALREQUEST
• Command aborted: External disk array replied ABORTEDCOMMAND
• Busy: The external disk array status is BUSY
• LDEV reserved: The external disk array status is Reserve
• Response error: The status of the external disk array is blocked because of an abnormal reply

(Response)

• Initiator port: The port attribute of the external disk array changed to initiator
• RCU target port: The port attribute of the external disk array changed to RCU target
• Unknown port: The port attribute of external disk array is unknown
• Cannot detect port: The path was removed or the external disk array port cannot be found
• Internal error: A program error occurred, or there is a logical contradiction
• Timeout: Processing was retried because of an abnormal reply, but a timeout has occurred
• Checking: External Storage XP is checking defined configuration information of paths
• Disconnect: The connection to the external disk array or LU was stopped using the Disconnect

Subsystem or Disconnect Volume command

• Unavailable: The external disk array replied Unavailable. The external disk array requests to

change the connected port. After the status becomes Unavailable, the primary path changes to

the alternate path that is in the Standby status. When the primary path changes, the status of the

path becomes Normal.

Advertising