HP StorageWorks 2.32 Edge Switch User Manual

Page 182

Advertising
background image

Information and error messages

182

Could not find firmware file.

Firmware file selected was not found
in the FTP directory. Or, the selected
file is not a firmware file.

Ensure file name and directory are correct.
Or, obtain a valid firmware file from your
service representative.

Could not remove dump files from
server.

Dump files could not be deleted from
the HAFM appliance because the link
may be down, or the HAFM
appliance or Element Manager is
busy.

Retry the operation later. If the condition
persists, contact the next level of support.

Could not stop port diagnostics.

Port diagnostics could not be stopped
by the Element Manager because the
Ethernet link is down or busy, or
because the director is busy.

Retry the operation later. If the condition
persists, contact the next level of support.

Could not write firmware to flash.

A firmware version could not be
written from the HAFM appliance to
FLASH memory

Retry the operation again. If the condition
persists, contact the next level of support.

Control Unit Port (CUP) name and
port name are identical (FICON
ONLY).

Within the address configuration, one
or more of the port names are the
same as the CUP name.

Make sure all names are unique for the
ports and CUP name.

Date entered is invalid.

The date is entered incorrectly at the
Configure Date and Time dialog box.
Individual field entries may be
correct, but the overall date is invalid
(for example, a day entry of 31 for a
30-day month).

Verify each entry is valid and consistent.

Device applications should be
terminated before starting
diagnostics. Press NEXT to
continue.

Port diagnostics (loopback tests)
cannot be performed on a port while
an attached device application is
running.

Terminate the device application and
perform diagnostics again.

[device WWN] cannot be removed
from the Switch Membership List
while participating in Switch
Binding. The device must be
isolated from the switch, or Switch
Binding deactivated before it can
be removed.

You attempted to remove a device
WWN from the Switch Membership
List (SANtegrity Binding feature) while
Switch Binding is enabled.

Remove the device from the switch by
blocking the port, setting the switch offline,
or disabling Switch Binding through the
Switch Binding Change State dialog box
before removing devices from the Switch
Membership List.

Table 8

Element Manager messages (continued)

Message

Description

Action