HP StorageWorks 2.32 Edge Switch User Manual

Page 52

Advertising
background image

Monitoring and managing the switch

52

Block configuration—Blocked or unblocked. Operation can be blocked or unblocked using

any of the following methods:
• Through the Configure Ports dialog box. See ”

Configuring ports

” on page 84 for instructions.

• Right-click a port in the Hardware View, a port’s row in the Port List View, or a port bar

graph in the Performance View, and click Block Port.

• Select Product > Port > Block Port. This option is available from the Hardware View,

the Port List View, or the Performance View.

10-100 km configuration—Extended distance buffering. This can be enabled or disabled

for the port through the Configure Ports dialog box. See

Configuring ports

” on page 84 for

instructions.

RX BB Credits—Indicates a switch that supports BB credit configuration.

LIN Alerts configuration—Indicates whether LIN alerts are enabled or disabled. LIN alerts

can be configured through the Configure Ports dialog box. The default is for the LIN alerts to be

enabled.

FAN configuration—Indicates whether Fabric Address Notification (FAN) is On or Off when

the port is operating as an FL_Port.

Beaconing—Indicates the beaconing status for the port. To enable or disable beaconing,

right-click the port and click Enable Beaconing. (A port in a failed state cannot be set to

beacon.)

Link incident—Description of the last link incident that occurred on the port.

Operational state—Beaconing, Inactive, Invalid Attachment, Link Incident, Link Reset, No

Light, Not Operational, Online, Offline, Port Failure, Segmented E_port, Testing, Or Not

Installed. See

Table 4

on page 72 for definitions of operational states.

Reason—When the port operating state is Segmented E_Port, Invalid Attachment, or Inactive,

this field displays the reason for that state. When an E_Port is segmented, two fabrics are

prevented from joining. This only occurs when the switch is connected to another switch.
The following messages display in the Reason field of the Port Properties dialog box if an

Invalid Attachment, Segmented E_Port, or Inactive state occurs for the port:
Invalid attachment messages:

01 Unknown

—The reason is not known.

02 ISL connection not allowed on this port

—ISL is connected to a port

configured as an F_Port.

03 ELP rejected by the attached switch

—This switch transmitted an exchange

link protocol (ELP) frame that was rejected by the switch at the other end of the ISL

04 Incompatible switch other end of the ISL

—The switch is configured for

Homogenous mode, and the switch at the other end of the ISL is an HP switch configured for

Open Fabric 1.0 mode.

05 External loopback adapter connected to the port

—A loopback plug is

connected to the port, and no diagnostic test is running.

06 N_Port connection not allowed on this port

—The port type configuration

does not match the actual port use. (The port is configured as an E_Port, but attaches to a

node device.)