Msa2000 3gb 3.5" 12-drive enclosure, Power supply leds, 18 leds — hp msa2000 3gb rear panel – HP P2000 G3 MSA Array Systems User Manual

Page 73

Advertising
background image

HP P2000 G3 iSCSI MSA System User Guide

73

MSA2000 3Gb 3.5" 12-drive enclosure

Power supply LEDs

Power redundancy is achieved through two independent load-sharing power supplies. In the event of a

power supply failure, or the failure of the power source, the storage system can operate continuously on a

single power supply. Greater redundancy can be achieved by connecting the power supplies to separate

circuits. DC power supplies are equipped with a power switch. AC power supplies may or may not have a

power switch (model shown below has no power switch). Whether a power supply has a power switch is

significant to powering on/off.

Table 18

LEDs — HP MSA2000 3Gb rear panel

LED

Description

Definition

1

Power supply LEDs

See

Power supply LEDs

on page 73.

2

Unit Locator

Off — Normal operation.

Blinking white— Physically identifies the expansion module.

3

SAS In Port Status

Green — Port link is up and connected.

Off — Port is empty or link is down.

4

OK to Remove

Not implemented.

5

Fault/Service Required

Amber — A fault has been detected or a service action is required.

Blinking amber — Hardware-controlled powerup or a cache flush

or restore error.

6

FRU OK

Green — Expansion module is operating normally.

Blinking green — System is booting.

Off — Expansion module is not OK.

7

SAS Out Port Status

Green — Port link is up and connected.

Off — Port is empty or link is down.

0

0

1

2

4

3

5

6 7

1

Advertising