Storage enclosure hard disk drives – HP StoreAll Storage User Manual

Page 54

Advertising
background image

NOTE:

Upon rebooting the storage controller after successful flash operation, wait until the storage

controller comes back online and is reachable. It may take as much as 45 to 60 minutes based
on storage configuration. During the flash operation, you will observe blinking of the UID on rear
side of the I/O module and the U3 or U5 code on the 7-segment display of the storage controller.

Storage enclosure hard disk drives

CAUTION:

Take care of the following prerequisite measures before performing a firmware update

operation on enclosure HDDs:

Ensure that the update of enclosure HDDs and I/O Modules is an OFFLINE process.

Ensure that all host and array I/O is stopped prior to the update.

Do not interrupt the setup while firmware is being updated. Ensure that the storage system
configuration is not being reconfigured during firmware update.

Ensure that no other user is performing administrative functions on the storage system.

Ensure that all file systems on the storage controller are unmounted. Failure to comply may
result in the operating system failing.

Example 46 Firmware update of the storage enclosure hard disk drives on the X9720 platform

# hpsp_fmt -f -c enclosure_hdd
Enclosure HDDs and IO Modules update is an OFFLINE process.

Please read through the following WARNING messages before continuing with the OFFLINE updates:
***WARNING***
- Ensure that all host and array I/O must be stopped prior to the update.
- Do not interrupt the setup while firmware is getting updated.
- Ensure that the storage system configuration is not being reconfigured during firmware update.
- Ensure that no other user is performing administrative functions on the storage system.
- Make sure all the filesystems are unmounted. Failure to comply may result in an OS crashing.

Please confirm you have read all the above warning messages and taken necessary actions (Y/N)?y

Do you want to proceed (Y/N)?y
Flashing Enclosure_HDD: Based on the configuration, it may take 15 minutes.
<<< Succeeded >>>
Flashing Enclosure_HDD: Based on the configuration, it may take 15 minutes.
<<< Succeeded >>>

--------------------------------------------------------------------------------
Device :Enclosure_HDD
Status :Success (Storage Ctlr Reboot Pending)
Code :0x1001
CONDITIONAL_SUCCESS :Flash succeeded for HP Storage Enclosure Hard
Disk Drives using CP018205.scexe. The attached storage
controller(s) must be restarted to complete the
operation.
Reboot Required :No
Coordinated Reboot Required :No
--------------------------------------------------------------------------------
Device :Enclosure_HDD
Status :Success (Storage Ctlr Reboot Pending)
Code :0x1001
CONDITIONAL_SUCCESS :Flash succeeded for HP Storage Enclosure Hard
Disk Drives using CP018290.scexe. The attached storage
controller(s) must be restarted to complete the
operation.
Reboot Required :No
Coordinated Reboot Required :No
--------------------------------------------------------------------------------

SUMMARY:
--------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
--------------------------------------------------------------------------------
Enclosure_HDD HP Storage Enclosure Hard No Success (Storage Ctlr Reboot Pending)
Disk Drives

Enclosure_HDD HP Storage Enclosure Hard No Success (Storage Ctlr Reboot Pending)
Disk Drives
--------------------------------------------------------------------------------

54

StoreAll 9730 and IBRIX X9720 FMT command reference and examples

Advertising