NetLinx Programming

100

MAX-CSE/MAX-CSD10 Operation/Reference Guide

I/O Port Commands (Port 4)

The I/O port is located at Port 4 in NetLinx D:P:S nomenclature.
In these examples: <DEV> = device.The I/O port supports the following commands.

IR RX Port Channels (Port 5)

I/O Send Commands

Command

Description

GET INPUT
Get the active state for the
selected channels.

An active state can be high (logic high) or low (logic low or contact closure).
Channel changes, Pushes, and Releases generate reports based on their
active state. The port responds with either 'HIGH' or 'LOW'.
Syntax:

SEND_COMMAND <DEV>,"'GET INPUT <channel>'"

Variable:

channel = Input channel 1 - 8.

Example:

SEND_COMMAND IO,"'GET INPUT 1'"

Gets the I/O port's active state.
The system could respond with:

INPUT1 ACTIVE HIGH

SET INPUT
Set the input channel's active
state.

An active state can be high (logic high) or low (logic low or contact closure).
Channel changes, Pushes, and Releases generate reports based on their
active state. Setting an input to ACTIVE HIGH will disable the ability to use that
channel as an output.
Syntax:

SEND_COMMAND <DEV>,"'SET INPUT <channel> <state>'"

Variable:

channel = Input channel 1 - 8.
state = Active state HIGH or LOW (default).

Example:

SEND_COMMAND IO,"'SET INPUT 1 HIGH'"

Sets the I/O channel to detect a high state change, and disables output on the
channel.

IR / Serial Ports Channels

00001 - 00255 PUSH and RELEASE channels for the received IR code.