Replacing hot-plug fans, Replacing hot-plug fans -53 – HP ProLiant DL740 Server User Manual

Page 152

Advertising
background image

Installing Hardware Options, Hot-Plug

Replacing Hot-Plug Fans

The ProLiant DL740 server ships with two hot-plug fans. Fan 1 is closest to the front
of the server. Each fan has an arrow-shaped status LED that indicates the status of the
fan the arrow is pointing to. Figure 5-26 shows an example of the hot-plug fan status
LEDs:

• Hot-plug fan 1 LED (1)—In this case the LED is amber, which means that the

fan needs attention or is not installed.

• Hot-plug fan 2 LED (2)—In this case the LED is green, which means that the fan

is installed, and working properly.

Figure 5-26: Hot-plug fan LEDs

CAUTION: Never remove both hot-plug fans while the server is powered up.
Overheating and damage to hardware could result. If the appropriate HP software
drivers are installed, the operating system software will initiate a power shutdown.

NOTE: The hot-plug fan LEDs are not part of the fan housing. Figure 5-26 shows the LEDs as
if the fan were installed in the server.

HP ProLiant DL740 Server User Guide

5-53

HP CONFIDENTIAL

Writer: Anna Roberts File Name: f-ch5 Installing Hardware Options Hot-Plug.doc

Codename: Expedition Part Number: 270854-002 Last Saved On: 6/17/03 2:09 PM