6 the, Total, Number – HP XP20000XP24000 Disk Array User Manual

Page 23: Differential, Tables, Migration, Plan

Advertising
background image

Table 6 The Total Number of the Differential Tables Per Migration Plan

Emulation Type

Expression

OPEN-3

Total number of the differential tables per migration plan = ((X) ÷ 48 + (Y) Ч

15) ч (Z)

(X): The capacity of the volume to be migrated. (kilobyte)*
(Y): The number of the control cylinders. (See

Table 7

on page 24)

(Z): The number of the slots that can be managed by a differential table.

(20,448)

Note that you should round up the number to the nearest whole number.
For example, if the emulation type of a volume is OPEN-3, and when provided

that the number of the cylinders of the volume is 2,403,360 kilobytes ((X) in the

expression above), the calculation of the total number of the differential tables

is as follows.
(2,403,360 ч 48 + 8 Ч 15) ч 20,448 = 2.454518779
When you round up 2.454518779 to the nearest whole number, it becomes 3.

Therefore, the total number of the differential tables for one migration plan is 3

when emulation type is OPEN-3.
One pair table can be used for 36 differential table. Therefore the total number

of the pair tables for one migration plan is 1 when emulation type is OPEN-3.

OPEN-8
OPEN-9

OPEN-E

OPEN-L

OPEN-V

Total number of the differential tables per migration plan = ((X) ч 256) ч (Z)

(X): The capacity of the volume to be migrated. (kilobyte)*
(Z): The number of the slots that can be managed by a differential table.

(20,448)

Note that you should round up the number to the nearest whole number.
For example, if the emulation type of a volume is OPEN-V, and when provided

that the number of the cylinders of the volume is 3,019,898,880 kilobytes ((X)

in the expression above), the calculation of the total number of the differential

tables is as follows.
(3,019,898,880 ч 256) ч 20,448 = 576.9014085
When you round up 576.9014085 to the nearest whole number, it becomes 577.

Therefore, the total number of the differential tables for one migration plan is

577 when emulation type is OPEN-V.
One pair table can be used for 36 differential table. Therefore the total number

of the pair tables for one migration plan is 17 when emulation type is OPEN-V.

The emulation type OPEN-V can only be used, if you use multiple pair tables on

the open system.

* If the volume is divided by the VLL function, this value means the capacity of the divided volume. Note

that if the emulation type is OPEN-L, the VLL function is unavailable.
The following table shows the number of the control cylinders according to the emulation types.