Virtual Connect networks 102

The Throughput Statistics configuration determines how often the Throughput Statistics are collected and the

supported time frame for sample collection before overwriting existing samples. When the time frame for
sample collection is reached, the oldest sample is removed to allocate room for the new sample.

Configuration changes can be made without having to enable Throughput Statistics. Applying configuration

changes when Throughput statistics is enabled clears all existing samples.
Some conditions can clear existing Throughput Statistics:

Disabling the collection of Throughput Statistics clears all existing samples.

Changing the sampling rate clears all existing samples.

Power cycling a VC-Enet module clears all Throughput Statistics samples for that module.

Collected samples are available for analysis on the Throughput Statistics screen (on page

228

), accessible

by selecting Throughput Statistics from the Tools pull-down menu.
The following table describes the available actions for changing Throughput Statistics settings.

Task

Action

Enable/disable

Select (enable) or clear (disable) the Enable Throughput Statistics checkbox.

Change sampling rate

Select a sampling rate from the Configuration list. Supported sampling rates

include:

Sample rate of 1 minute, collecting up to 5 hours of samples.

Sample rate of 2 minutes, collecting up to 10 hours of samples.

Sample rate of 3 minutes, collecting up to 15 hours of samples.

Sample rate of 4 minutes, collecting up to 20 hours of samples.

Sample rate of 5 minutes, collecting up to 25 hours of samples.

Sample rate of 1 hour, collecting up to 12.5 days of samples.

LACP timer configuration

Virtual Connect provides two options for configuring uplink redundancy (Auto and Failover). When the

connection mode is set to "Auto", VC uses Link Aggregation Control Protocol to aggregate uplink ports from

a Network or Shared Uplink Set into Link Aggregation Groups. As part of the LACP negotiation to form a
LAG, the remote switch sends a request for the frequency of the control packets (LACPDU). This frequency can

be "short" or "long." Short is every 1 second with a 3 second timeout. Long is every 30 seconds with a 90

second timeout.
Prior to VC 4.01 this setting defaulted to short. Starting with VC v4.01 this setting can be set to short or long.
The domain-wide setting can be changed on the Ethernet Settings (Advanced Settings) screen ("

Ethernet

Networks (Advanced Settings)

" on page

97

). Additionally, each Network or Shared Uplink Set also has a

LACP timer setting. There are three possible values: Domain-Default, Short, or Long. The domain default

option sets the LACP timer to the domain-wide default value that is specified on the Advanced Ethernet
Settings screen.
This setting specifies the domain-wide default LACP timer. VCM uses this value to set the duration of the LACP

timeout and to request the rate at which LACP control packets are to be received on LACP-supported

interfaces. Changes to the domain-wide setting are immediately applied to all existing networks and shared

uplink sets.
Using the "long" setting can help prevent loss of LAGs while performing in-service upgrades on upstream