HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 251

Advertising
background image

Virtual Connect modules 251

Port Statistic

Description

IfHCOutMulticastPkts

The total number of packets that higher-level protocols requested be

transmitted, and which were addressed to a multicast address at this

sublayer, including those that were discarded or not sent. For a MAC

layer protocol, this includes both Group and Functional addresses. This
object is a 64-bit version of ifOutMulticastPkts.

IfHCOutBroadcastPckts

The total number of packets that higher-level protocols requested be

transmitted, and which were addressed to a broadcast address at this
sublayer, including those that were discarded or not sent. This object is a

64-bit version of ifOutBroadcastPkts.

cosq<N>_ucast_DroppedPkts

The accumulated dropped packet count of unicast packet of the queue for

the specified port. For VC FlexFabric 10Gb/24-port module and VC
Flex-10 Enet module, the counter includes unicast and multicast data.

cosq<N>_ucast_OutBytes

The accumulated transmitted byte count of unicast packets of the queue for

the specified port. For VC FlexFabric 10Gb/24-port module and VC

Flex-10 Enet module, the counter is not supported and the value is 0.

cosq<N>_ucast_OutPkts

The accumulated transmitted packet count of unicast packets of the queue

for the specified port. For VC FlexFabric 10Gb/24-port module and VC

Flex-10 Enet module, the counter includes both unicast and multicast data.

*These statistics appear for physical uplink ports, physical downlink ports, and Flex-10 subports. All other statistics only

appear for physical uplink and downlink ports.

Remote Device Information*

Description

remote_type

Type of remote device. Virtual Connect uses this information to configure

the link as an uplink, a stacking link, or to disable. This information is

based on the LLDP data sent by the device to which the port is attached.

remote_discovered_time

Time the remote device was identified, represented in seconds. This
information is based on the LLDP data sent by the device to which the port

is attached.

remote_chassis_id_type

Chassis ID subtype of the remote device

remote_chassis_id

Chassis ID value of the remote device

remote_port_id_type

Port ID subtype of the remote device

remote_port_id

Port ID value of the remote device

remote_port_desc

Port description of the remote device

remote_system_name

System name of the remote device. If the remote device is a VC-Enet

module, remote_system_name is the remote device's VC domain name.

remote_system_desc

Description of the remote system. If the remote device is a VC-Enet module,

remote_system_desc is the module's hardware description and firmware
revision.

remote_system_capabilities

System capabilities of the remote system, for example, repeater, bridge,

or router

remote_mgmt_addr_type

Management address subtype of the remote device, for example, IPv4,
IPv6, or DNS

remote_mgmt_addr

Management address of the remote device

*This information is only available for physical uplink and downlink ports. It is not available for Flex-10 subports.

Pluggable Module Information* Description

identifier

Identifies the type of serial transceiver. The binary values are defined in

SFF-8472 in the Identifier [Address A0h, Byte 0] field. This field displays
an ASCII representation of those binary values.

Advertising