Battery – HP ProLiant DL120 G7 Server User Manual

Page 82

Advertising
background image

Battery 82

Battery

If the server no longer automatically displays the correct date and time, you may need to replace the battery

that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.

WARNING:

The computer contains an internal lithium manganese dioxide, a vanadium

pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Replace only with the spare designated for this product.

To remove the component:

1.

Power down the server (on page

17

).

2.

Extend or remove the server from the rack ("

Remove the server from the rack

" on page

17

).

3.

Remove the access panel (on page

18

).

CAUTION:

To prevent damage to the server or expansion boards, power down the server and

remove all AC power cords before removing or installing the expansion boards.

4.

Remove the battery.

IMPORTANT:

Replacing the system board battery resets the system ROM to its default

configuration. After replacing the battery, reconfigure the system through BIOS Setup Utility.

To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact an authorized reseller or an

authorized service provider.