Table 28 control cylinders by emulation type, 28 control cylinders by emulation type – HP XP Business Copy Software User Manual

Page 83

Advertising
background image

Business Copy XP user guide for the XP10000/XP12000

83

Calculating differential tables for open-system volume migration

When you migrate open-system volumes, use the information in

Table 27

to calculate the total number of

required differential tables per migration plan.

The following table shows the number of control cylinders according to the emulation type.

Table 27

Total number of differential tables per migration plan

Emulation type

Equation

OPEN-3

Total number of differential tables per migration plan =

(X): Capacity of the volume to be migrated (KB)

1,2

(Y): Number of control cylinders associated with the emulation type (see

Table 28

)

(Z): Number of slots that can be managed by a differential table

NOTE:

Round the result of the calculation up to the nearest whole number.

For example, if the volume’s emulation type is OPEN-3, and it is not a custom volume, the

volume capacity (X) is the default volume size, 2,403,360 KB, and the total number of

differential tables is calculated as follows:

When you round to the nearest whole number, the result is 1. Therefore, the total number of

differential tables for one migration plan is 1 when the emulation type is OPEN-3.

1. If the selected volume is a CVS (custom volume size) volume, use the capacity of the custom volume instead of the default volume

capacity for the emulation type. Since the OPEN-L emulation type does not support custom volume operations, you must use the

default volume capacity of OPEN-L for X.

2. 1 KB equals 1024 bytes.

OPEN-8

OPEN-9

OPEN-E

OPEN-L

OPEN-V

Total number of differential tables per migration plan =

(X): Capacity of the volume to be migrated (KB)

2

(Z): Number of slots that can be managed by a differential table

NOTE:

Round the result of the calculation up to the nearest whole number.

For example, if the volume capacity (X) is the maximum OPEN-V volume capacity of

3,019,898,880 KB, the total number of differential tables is calculated as follows:

When you round up to the nearest whole number, the result is 193. Therefore, the total number

of differential tables for migration plan is 193 when the emulation type is OPEN-V.

Table 28

Control cylinders by emulation type

Emulation type

Number of control cylinders

OPEN-3

8 (5,760KB)

OPEN-8

27 (19,440KB)

OPEN-9

OPEN-E

19 (13,680KB)

OPEN-L

7 (5,040KB)

OPEN-V

0 (0KB)

X 48

÷

(

)

Y 15

×

(

)

+

[

]

Z

ч

1,916 32

Ч

(

)

2,403,360 48

ч

(

)

8 15

Ч

(

)

+

[

]

1,916 32

Ч

(

)

ч

0.81860

=

X 256

÷

(

)

Z

( )

ч

1,916 32

Ч

(

)

3,019,898,880 256

ч

(

)

1,916 32

Ч

(

)

ч

192.40084

=