Configuring Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director

The following sections contain procedures for obtaining chassis information and for configuring director

domains using the

chassisConfig

command.

Obtaining slot information

For a Core Switch 2/64 or SAN Director 2/128 configured as two logical switches, the chassis-wide

commands display or control both logical switches. In the default configuration, the SAN Director 2/128

and 4/256 SAN Director are configured as one logical switch, so the chassis-wide commands display

and control the single logical switch.

Displaying the status of all slots in the chassis

1.

Connect to the switch and log in as user or admin.

2.

Issue the

slotShow

command to display the current status of each slot in the system.

The format of the display includes a header and four fields for each slot. The fields and their possible

values are:

4

2

64/64

Left side: FC-16

Right side: FC2-16

CP2

N/A

Two 64-port

switches (Blade

ID 2 on slots

1–4; ID 4 on

slots 7–10.

Blade ID 5 on

slots 5, 6)

5

1

256

FC4-16, FC4-32

CP4

CP4 fits all chassis

except the D2

chassis. Option 5

is the default

configuration

option for 4/256

SAN Director.

One 256-port

switch (Blade

IDs 4, 17, and

18 on slots 1–4,

7–10. Blade ID

16 on slots 5, 6)

Table 17

Supported configuration options (continued)

Option Number of

domains

Maximum number

of ports per switch

Supported port

blades

Supported

CP blades

Notes

Results

Field

Value

Slot

Displays the physical slot number.

Blade Type

Displays the blade type:

SW BLADE

: The blade is a switch.

CP BLADE

: The blade is a CP.

UNKNOWN

: The blade is not present or its type is not recognized.

ID

Displays the hardware ID of the blade type.

Advertising