Allied Telesis AT-FS238a/2 User Manual

Page 33

Advertising
background image

AT-FS238a/x and AT-FS238b/x Series Installation Guide

21

Note
UL recognized wires of 22-gauge minimum should be provided by the
installer.

5.

With a 22-gauge wire-stripping tool, strip the three wires in the tray cable
coming from the DC input power source to 8mm ± 1mm
(0.31in.± 0.039in.), as shown in Figure 11 on page 21.

Warning
Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by
leaving exposed wire on the terminal block after installation.

17

Figure 11 Stripped Wire

6.

Connect the ground wire to the terminal marked with the ground symbol
by inserting the wire into power connector that comes with the converter
and tightening the connection with a flathead screwdriver, as shown in
Figure 12.

Warning
When installing this equipment, always ensure that the frame ground
connection is installed first and disconnected last.

18

Figure 12 Connecting the Stripped Wire

7.

Connect the negative feed wire to the terminal block marked (-).

8.

Connect the positive feed wire to the terminal block marked (+).

Advertising