Switch node port, Attributes, Transceiver physical – HP NonStop G-Series User Manual

Page 259: Logical, Switch node port transceiver physical logical

Advertising
background image

Switch Node Port

On the

6780 switch

, an external transceiver port that connects to a ServerNet node.These ports reside only on switch

PICs in slots 6 through 9.

Location in OSM tree: External ServerNet Fabric > Switch Group > Switch Module > Switch PIC > Switch Port

Example: Switch Port (1010.1.6.1)

See also

Router Connections for Switch Node Ports

.

Attributes

Switch Node Port

Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK.

Values

Service State

Transceiver Physical

The type of transceiver.
Example: 9/125 Micron SMF

Type

The vendor part number of the transceiver.

Part Number

The vendor serial number of the transceiver.

Serial Number

Identifies the manufacturer of the component.

Manufacturer

The vendor hardware revision of the transceiver.

Hardware Revision

Logical

The status of the port.
Values:

Port reset
Loss of optical signal
Transceiver absent
PIC absent
No link alive
Link Alive - Port disabled
Neighbor check in progress
Neighbor check complete - Port disabled
Neighbor check failed - No link alive
Connected to switch
Connected to switch with wrong numeric selector
Connected to switch with invalid configuration version identifier
Connected to wrong port
Connected to different switch
Connected to switch with incompatible configuration
No response to Manage Port command from neighbor port
Manage Port command not acknowledged (NACKed) from neighbor port
Port enabled
Invalid
Unknown

Connectivity Status

The speed of the port in bits per second.

Current Speed

The initial state of the component at the time of discovery.
Values: OK, Fault

Transceiver Device State

Whether the transceiver is enabled.
Enabled: The component is operational.

Disabled: The component is present but not operational.

Transceiver Enabled State

The state of the external ServerNet fabric from the local node to the remote node
connected via this port.
Up: At least one of the processors on the local node can communicate with at least
one processor on one of the remote nodes.

Down: No processor on the local node can communicate with any processor on any
remote node.

Fabric State

Switch Node Port

259