Adv Setup

Adv Setup offers expert users access to more advanced system settings.

To access this option, hold down the ESC key for two seconds until it appears.

11. Adv Setup

Read Error Skip

This function sets the system to ignore any errors during the copying process. Normally if there is

an error during copying a warning is displayed on the LCD. By using this function, users can also

copy a HDD with errors.

11-01. Adv Setup

Read Error Skip

Update Firmware

This function is used to update the system's firmware. Download the latest version of the firmware

from the Internet at www.addonics.com. For the complete instructions, visit the firmware update

webpage or view the instructions found later in this manual.

11-02. Adv Setup

Update Firmware

Read Error Skip

Off

Press ENT to enter the following screen. By default this option is set to OFF. Use the up and down

buttons to enable or disable this option.

Quick Erase HDD

This function is used to quickly erase all data on the HDD

. Please backup any important data

before using this function.

11-04.Adv Setup

Quick Erase HDD

Quick Erase HDD

ALL/Target CH:*

Press ENT to enter the following screen. Use the Up and Down

buttons to select the HDD to

erase.

Compare Firmware

This function is used to compare the current system firmware version with the new version the user

is upgrading to. This ensures that the downloaded firmware is the latest version. The message

"Last update F/W" indicates that it is the latest version.

11-03.Adv Setup

Compare Firmware

Searching F/W ...

Please Wait ...

Last update F/W

OK!