HP NonStop G-Series User Manual

Page 155

Advertising
background image

Initialized

Whether the processors and service processors have been
initialized after the most recent power-on.

True: Processors and service processors have been
initialized.

False: Processors and service processors have not been
initialized.

Halt Code

The octal halt code emitted by the processor that halted.

0: No halt has occurred.

%53: System freeze occurred.

%74: Software fault occurred.

For details, see

Lites Register

.

Backpressure State on Internal X Fabric

Whether persistent backpressure is severe enough to
disrupt traffic on the Internal ServerNet X Fabric.

Fault: Backpressure has caused ServerNet traffic on the
Internal ServerNet X Fabric to become blocked.

OK: Backpressure levels are below the threshold level for
disrupting ServerNet traffic.

Unknown: Cannot be determined.

Backpressure State on Internal Y Fabric

Whether persistent backpressure is severe enough to
disrupt traffic on the Internal ServerNet Y Fabric:

Fault: Backpressure has caused ServerNet traffic on the
Internal ServerNet Y Fabric to become blocked.

OK: Backpressure levels are below the threshold level for
disrupting ServerNet traffic.

Unknown: Cannot be determined.

Hardware Freeze Flag

Whether the processor has been frozen by a hardware
error:

True: A hardware error in this processor caused it to
freeze. (Disregard the Halt Code and Lites Register
values.)

False: This processor has not experienced a freeze caused
by a hardware error.

Unknown: Hardware freeze state could not be read.

Online Boot Millicode Firmware

Online Boot Millicode Firmware Update is not supported for processors in S7000 PMF CRUs or on

Advertising