Table 63 SIM (continued)

Description

Importance level

SIM type (byte
28)

Reference code

SSB13

SSB23

SSB22

inaccessible because the power supply was turned
on while the shared memory volatilized.

Once either SIM=4B2xYY or SIM=4B4xYY is output,
further output of either type of SIM is inhibited for five

Service

F1

05

F1

7F

minutes. (For example, if SIM=4B4111 is output,
SIM=4B4xYY is not output for five minutes, regardless
of xYY.) This SIM reports the occurrence of this
inhibition.