status

View overall domain status information.
Supported actions:

help, show

Item Description

show status

Display the status of the domain and all components in the domain

Syntax

show status

Example

->show status

Displays domain status information

systemlog

View Virtual Connect Manager system event log.
Supported actions:

help, show

Item Description

show systemlog

Display the Virtual Connect manager system log

Syntax

show systemlog

Example

->show systemlog

Displays the system log

uplinkport

Manage interconnect module uplink ports.
Supported actions:

add, help, remove, set, show

Item Description

add uplinkport

Add a new uplink port to an existing network or a shared uplink port set

Syntax

add uplinkport <PortID> [Network=<NetworkName> |
UplinkSet=<UplinkSet>] [Speed=<Auto|10Mb|100Mb|1Gb|Disabled>]

Parameters:

PortID

The ID of an uplink port to add (required). The name is actually a combination of the

enclosure name, interconnect bay, and port number in a single descriptor. The
format of the port name is
"

<EnclosureID>:<InterconnectBay>:<PortNumber>

". If Enclosure ID is not

specified, it defaults to the local enclosure.

Properties:

Network

The name of an existing network to which the port is added

UplinkSet

The name of an existing shared uplink port set to which the port is added

Speed

Specifies the port speed for the port (optional). Acceptable values include Auto,
10Mb, 100Mb, 1Gb, and Disabled. If not specified, the default port speed is

"Auto".

Examples: