HP EVA P6000 Storage User Manual

Page 133

Advertising
background image

Table 22 iSCSI or iSCSI/FCoE module secret settings

MS Initiator secret settings

iSCSI or iSCSI/FCoE module secret settings

Setting (example)

Action

Setting (example)

Source

N/A

General Tab Secret

N/A

iSCSI Port

CHAPsecret01

Add Target Portal

CHAPsecret01

Discovered iSCSI Initiator

CHAPsecret01

Log on to Target

N/A

iSCSI Presented Target

NOTE:

These are examples of secret settings. Configure CHAP with settings that apply to your specific network

environment.

1.

Enable CHAP for the iSCSI or iSCSI/FCoE modules discovered iSCSI Initiator entry. CHAP
can be enabled via CLI only. To enable CHAP for the iSCSI or iSCSI/FCoE modules discovered
iSCSI Initiator entry using the iSCSI or iSCSI/FCoE module's CLI:
a.

If the iSCSI Initiator is not listed under set chap command:

HP Command View Option: add the initiator iqn name string via HP Command
View’s add host tab.

Go to the HP P6000 Command View and select Hosts then select Add Host tab
and enter the iqn name string.

CLI Option: Enter the initiator add command and add the iSCSI Initiator that is about
to do discovery.

b.

If the iSCSI Initiator is listed under set chap command, then enable CHAP secret. For
example: CHAPsecret01:

Select the index of the iSCSI Initiator.

To Enable CHAP, select 0, then type the CHAP secret.

Set up the iSCSI Initiator

133

Advertising