48

Signal and Power-Up Requirements

Chapter 9

AMD Athlon™ XP Processor Model 8 Data Sheet

25175H—March 2003

Preliminary Information

Clock Multiplier
Selection (FID[3:0])

The chipset samples the FID[3:0] signals in a chipset-specific
manner from the processor and uses this information to
determine the correct serial initialization packet (SIP). The
chipset then sends the SIP information to the processor for
configuration of the AMD Athlon system bus for the clock
multiplier that determines the processor frequency indicated
by the FID[3:0] code. The SIP is sent to the processor using the
SIP protocol. This protocol uses the PROCRDY, CONNECT, and
CLKFWDRST signals, that are synchronous to SYSCLK.

For more information about FID[3:0], see “FID[3:0] Pins” on
page 75.

Serial Initialization Packet (SIP) Protocol. R e f e r t o A M D A t h l o n ™
System Bus Specification
, order# 21902 for details of the SIP
protocol.

9.2

Processor Warm Reset Requirements

Northbridge Reset
Pins

RESET# cannot be asserted to the processor without also being
asserted to the Northbridge. RESET# to the Northbridge is the
same as PCI RESET#. The minimum assertion for PCI RESET#
is one millisecond. Southbridges enforce a minimum assertion
of RESET# for the processor, Northbridge, and PCI of 1.5 to 2.0
milliseconds.