Attributes – HP NonStop G-Series User Manual

Page 161

Advertising
background image

A processor and memory board (PMB), which contains a

processor

A

power supply

(S7000 only)

A

service processor (SP)

Three

SCSI controllers

And for PMFs in Group 1 only, an

MIOE

(Ethernet controller) to provide connectivity

between the service processor and the dedicated service LAN (for OSM).

Location in OSM Tree: System > Group > Module > PMF

Slot Location: PMF CRUs are located in slots 50 and 55 of a processor enclosure (service side).

Example: PMF (1.1.55)

Attributes

PMF

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Physical

Hardware Revision

A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.

Manufacturer

Identifies the manufacturer of the component.

Part Number

The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.

Power State

Whether the component is powered on.

Values

Track ID

A unique serial number that identifies the component. Track IDs are used for
tracking components.

Logical

Fan Voltage

The current voltage of the Fan CRU.

Main Rail Voltage

The voltage of the Main Rail, which supplies power to the CRU from its
own power supply

Disabled ServerNet Ports

This attribute indicates which, if any, ServerNet router ports on this CRU
are disabled. OSM actions to disable or enable a ServerNet port are
performed as directed by OSM alarm repair actions.

SCSI-Y Voltage

The voltage of the SCSI-Y path, the path configured for mirrored disks on
a system.

Advertising