7.17

Configuring Rules for Email Alerts

System Reporter 2.8

3PAR System Reporter User’s Guide

7.4.4.7 Limit Count

The alert will only be generated if the number of objects for which the Metric exceeds the

Limit Value (in the direction specified by Direction) is greater than Limit Count in any given

sample. This should be an integer.

7.4.4.8 Condition

Specifies the condition (min_read_iops, min_write_iops, min_total_iops) that should be

monitored.

7.4.4.9 Condition Value

Specifies the condition value.

7.4.4.10 Recipient

Email address to which the alert email should be sent.

7.4.5 Example of an Alert Rule

Figure 7-3

shows an example of a configured alert. In this example, System Reporter will send

an email alert to email@address each time it inserts a high-resolution sample in which more

than 0 (Limit Count) VLUNs (including VLUNs in all systems) has a total (reads and writes

included) average service time in millisecs of greater than (>) 1000 (Limit Value).

Figure 7-3. Example of an alert rule

An example of the email alert is shown

Figure 7-4

:

Figure 7-4. Example of an alert email