Advanced ecc memory, Dimm installation guidelines, Dimm population order – HP ProLiant BL495c G5 Server-Blade User Manual

Page 21: Installing dimms

Advertising
background image

Advanced ECC memory

Advanced ECC memory is the default memory protection mode for this server blade. In Advanced ECC,

the server blade is protected against correctable memory errors. The server blade provides notification if

the level of correctable errors exceeds a pre-defined threshold rate. The server blade does not fail
because of correctable memory errors. Advanced ECC provides additional protection over Standard ECC

because it is possible to correct certain memory errors that would otherwise be uncorrectable and result in

a server blade failure.
Whereas standard ECC can correct single-bit memory errors, Advanced ECC can correct single-bit

memory errors and multi-bit memory errors if all failed bits are on the same DRAM device on the DIMM.

DIMM installation guidelines

CAUTION:

Always wear an antistatic wrist strap when working inside the server.

Observe the following guidelines when installing additional memory:

Install only ECC PC2-5300 Registered DDR2 SDRAM DIMMs

Always install DIMMs in sequence (1A, 2A, 3B, 4B).

DIMMs must always be installed in pairs.

HP recommends installing DIMMs with the greatest capacity in the banks farthest from each
populated processor first.

mber.

DIMMs installed in the same memory bank must have the same part nu

DIMMs installed in different banks can be of different sizes.

nel mode and Advanced ECC. To select a mode, use RBSU ("

HP ROM-Based Setup Utility

"

on page

40

).

A

D

2F

14G

H, 16H

For DIMM slot locations, see "System board components (on page

8

)."

Each server supports multiple memory modes, based on DIMM population. The system will default to

combined chan

DIMM population order

Bank A

1A, 2

Bank B

3B, 4B

Bank C

5C, 6C

Bank D

7D, 8

Bank E

9E, 10E

Bank F

11F, 1

Bank G

13G,

Bank H

15

Single

processor

1st

2nd

3rd

4th

— — — —

Two

processors

1st 3rd 5th 7th 2nd 4th 6th

8th

Installing DIMMs

surfaces, allow the drives and the

internal system components to cool before touching them.

WARNING:

To reduce the risk of personal injury from hot

To install the component:

1.

Power down the server blade (on page

11

).

Hardware options installation 21

Advertising