Parameter Default

value

Definition

Session Timeout
(minutes)

30 minutes

This parameter specifies how many minutes a session can
remain inactive before RILOE II the user is required to log in
again.

ROM configuration
utility (F8)

Enabled

This parameter enables or disables the use of the F8 key,
during POST, to access the Remote Insight ROM
Configuration Utility.

Emergency
Management Services

Enabled

This parameter enables or disables the use of the Windows
.NET EMS through RILOE II.

Bypass Reporting Of
External Power Cable

Disabled

This parameter determines if RILOE II reports whether or not
the external power cable is connected to the operating
system agent. If this settings is Enabled and there are no
other status problems, Insight Manager reports a green
status.

If this parameter is Disabled, RILOE II reports the true status of
the external power connector to the operating system agent.
Insight Manager reports RILOE II status as degraded if the
external connector is disconnected.

Remote Console Port
Configuration

Enabled

This parameter determines how the Remote Console port is
configured. There are three options:

Enabled allows administrators to specify the Remote
Console port.

Disabled prevents administrators from designating a
Remote Console port.

Automatic uses the default port.

Remote Access with
Pocket PC

Enabled

This parameter enables or disables access to RILOE II through
a Pocket PC client.

Remote Console Data
Encryption

Enabled

This parameter determines if data communication with the
Remote Console is encrypted. Encryption (enabled) helps
keep your remote console session private on the network. If
you intend to use a standard telnet client to access a RILOE II,
this parameter must be disabled.

SSL Encryption
Strength

128-bit

This parameter displays the current cipher strength setting.
The most secure is 128-bit (High).

Current Cipher

N/A

This parameter displays the encryption algorithm currently
being used to protect data during transmission between the
browser and RILOE II. The algorithm is negotiated by RILOE II
and the browser.

Remote Insight HTTP
Port

80

The embedded web server in RILOE II is configured by
default to use port 80 for unencrypted communications.

Remote Insight HTTPS
Port

443

The embedded web server in RILOE II is configured by
default to use port 443 for encrypted communications.

Remote Insight
console Port

23

RILOE II Remote Console is configured by default to use port
23 for Remote Console communications.

Host Keyboard Model

US

This parameter enables you to specify the language model of
the keyboard during a Remote Console session.