HP StorageWorks ESL9000 Tape Library User Manual

Page 119

Advertising
background image

Sense Data Values

119

HP StorageWorks ESL9000 Series Tape Library User Guide

02

04

00

LU IS NOT READY, CAUSE NOT REPORTABLE

Check library power. Retry command.

02

04

01

LOGICAL UNIT IN PROCESS OF BECOMING READY

Wait for library to complete initialization.

02

04

02

LOGICAL UNIT INIT REQUIRED

Element status or calibration unknown. Run an inventory command.

02

04

03

LU IS NOT READY, MANUAL INTERVENTION REQ’D

Initialization failed. Determine failure type by checking any previous error

code in the error log. Correct the cause of the failure and toggle Standby

button.

02

5A

01

OPERATOR MEDIUM REMOVAL REQUEST

Indicates that the element contains a cleaning cartridge that is used-up

and the library is unable to export the cleaning cartridge. Manually

unload the tape, and replace it with a new cleaning cartridge.
The load port door is open, so import/export elements can not be

accessed. Close the load port door.

02

80

00

DOOR IS OPENED INVENTORY MAY HAVE BEEN CORRUPTED

Close door and retry command. If the library is on-line, it executes its

initialization procedure. If not done automatically, run an inventory

command.

02

80

07

SYSTEM IS STOPPED (BUTTON IS CURRENTLY PUSHED)

The Stop button on the control panel was pressed. Press the Stop button

again to reactivate the robotics.

02

80

09

LOGICAL UNIT IS TURNED OFF-LINE

The library is ready to communicate with the diagnostic PC. Press the

Standby button on the control panel to place the library on-line.

04

80

00

GRIPPER AXIS INTERNAL FAIL

Upgrade firmware to latest revision.
Call your authorized service provider.

04

80

0A

NVRAM CHECKSUM FAILURE

Nonvolatile RAM contents are corrupted. Run the

INITIALIZE

NON-VOLATILE CONFIG

command and then a

CALIBRATE ALL

command.
Call your authorized service provider.

Table 26: Sense Data Values (Hexadecimal) (Continued)

Sense

Key

ASC

ASCQ

Message Name/Description

Advertising