Troubleshooting common problems, Start up problems, Table 14: start up problems – HP StorageWorks ESL9000 Tape Library User Manual

Page 90: 14 start up problems

Advertising
background image

Maintenance and Troubleshooting

90

HP StorageWorks ESL9000 Series Tape Library User Guide

Troubleshooting Common Problems

This section describes problems you might encounter during the setup and
operation of the HP StorageWorks ESL9000 Series tape library. Corrective
information is provided to help you resolve the problems.

Several of these problems produce error messages on the control panel called
sense data values. Sense data value messages consist of a number and a
description of the error. For a complete list of sense data values, see Appendix C,

Sense Data Values

.”

The troubleshooting information in this section includes the following topics:

Start Up Problems

Control Panel Problems

Robotics Problems

Operating Problems

Tape Drive Problems

Start Up Problems

Table 14

lists corrective actions for problems that might occur during start-up. If

the problems persist, contact your authorized service provider.

Table 14: Start Up Problems

Problem

Corrective Action

The library does not

power on.

Make sure the power cord is connected to a

grounded electrical outlet.

Make sure that the power distribution assembly (left

rear corner of cabinet) circuit breaker is on.

Make sure that all power supplies are switched on.

Make sure that the power switch behind the slide

panel just below the control panel is on.

The library or tape

drives do not respond

on the SCSI bus.

Make sure each SCSI device on the same SCSI bus has a

unique address and the last device is properly terminated

Advertising