Adding drives – HP Smart Array P731m Controller User Manual

Page 28

Advertising
background image

Drive procedures 28

2.

Power down the system.

3.

Move the drives.

4.

Power up the system.

5.

Observe the POST messages:

o

If a 1785 POST message appears, the drive array did not configure properly. Continue with step 6.

o

If a 1724 or 1727 POST message appears, drive positions were changed successfully and the
configuration was updated. Continue with step 7.

6.

If the array did not configure properly, do the following:

a.

Power down the system immediately to prevent data loss.

b.

Return the drives to their original locations.

c.

Restore the data from backup, if necessary.

7.

Verify the new drive configuration by running HP SSA ("

Configuring an array

" on page

16

).

Adding drives

You can add drives to a system at any time, if you do not exceed the maximum number of drives that the

controller supports. You can then either build a new array from the added drives or use the extra storage

capacity to expand the capacity of an existing array.
If the drives that you intend to add to the system are already configured into logical drives, you must meet

certain conditions before adding drives to the system. For more information, see "Moving drives and arrays

(on page

27

)." When you have successfully added the drives, reset the server so that the controller can

recognize the logical drives.
To perform an array capacity expansion, use HP SSA. If the system uses hot-pluggable drives and HP SSA

runs in the same environment as the normal server applications, you can expand array capacity without

shutting down the operating system. For more information, see the HP Smart Storage Administrator User

Guide on the HP website (

http://www.hp.com/go/smartstorage/docs

).