HP Smart Array P731m Controller User Manual

Page 7

Advertising
background image

Component identification 7

1 - Amber

2 - Green

3 - Green

Interpretation

Off

Flashing once

every 2 seconds

Flashing once

every 2 seconds

The cache microcontroller is executing from within its

boot loader and receiving new flash code from the host
controller.

Off

Flashing once

per second

Flashing once

per second

The cache module is powering up, and the capacitor

pack is charging.

Off

Off

Flashing once
per second

The cache module is idle, and the capacitor pack is
charging.

Off

Off

On

The cache module is idle, and the capacitor pack is

charged.

Off

On

On

The cache module is idle, the capacitor pack is charged,

and the cache contains data that has not yet been
written to the drives.

Off

Flashing once

per second

Off

A backup of the DDR content on the cache module is in

progress.

Off

On

Off

The current backup is complete with no errors.

Flashing once

per second

Flashing once

per second

Off

The current backup failed, and data has been lost.

Flashing once
per second

Flashing once

per second

On

A power error occurred during the previous or current

boot. Data may be corrupt.

Flashing once
per second

On

Off

An overtemperature condition exists.

Flashing twice
per second

Flashing twice

per second

Off

The capacitor pack is not attached.

Flashing twice
per second

Flashing twice
per second

On

The capacitor has been charging for 10 minutes, but
has not reached sufficient charge to perform a full

backup.

On

On

Off

The current backup is complete, but power fluctuations

occurred during the backup.

On

On

On

The cache module microcontroller has failed.

Advertising