Intelligent drive array (cpqida.mib) – HP Insight Management for Tivoli User Manual

Page 25

Advertising
background image

Appendix B: HP SNMP events 25


Trap types

Rules file

Description

Netcool

severity

cpqSiSysBatteryFailure
(2011)

2011

This event occurs when the battery
indicated by cpqSiSysBatteryIndex

has failed and must be replaced.

Major (4)

cpqSiSysBatteryChargingDe

graded (2012)

2012

This event occurs when Significant

battery degradation has occurred
and the battery can no longer be
fully recharged.

Major (4)

cpqSiSysBatteryCalibration

Error (2013)

2013

This event occurs when Calibration

is needed with battery and the
battery cannot correctly indicate
capacity.

Major (4)

Intelligent drive array (CPQIDA.MIB)

Trap types

Rules file

Description

Netcool

severity

cpqDa3LogDrvStatusChang
e (3008)

This event occurs when the
status of a drive array logical

drive changes.

CpqDaLogDrvStatus:ok

CpqDaLogDrvStatus.2

Clear (0)

CpqDaLogDrvStatus:failed CpqDaLogDrvStatus.3

Critical (5)

CpqDaLogDrvStatus:recover
ing

CpqDaLogDrvStatus.4

Minor (3)

CpqDaLogDrvStatus:unconfi
gured

CpqDaLogDrvStatus.5

Minor (3)

CpqDaLogDrvStatus:readyF
orRebuild

CpqDaLogDrvStatus.6

Minor (3)

CpqDaLogDrvStatus:rebuild

ing

CpqDaLogDrvStatus.7

Minor (3)

CpqDaLogDrvStatus:wrong

Drive

CpqDaLogDrvStatus.8

Minor (3)

CpqDaLogDrvStatus:badCo

nnect

CpqDaLogDrvStatus.9

Major (4)

CpqDaLogDrvStatus:overhe

ating

CpqDaLogDrvStatus.10

Major (4)

CpqDaLogDrvStatus:shutdo

wn

CpqDaLogDrvStatus.11

Major (4)

CpqDaLogDrvStatus:expan

ding

CpqDaLogDrvStatus.12

Minor (3)

CpqDaLogDrvStatus:notAva
ilable

CpqDaLogDrvStatus.13

Minor (3)

CpqDaLogDrvStatus:queued
ForExp

CpqDaLogDrvStatus.14

Minor (3)

CpqDaLogDrvStatus:multipa
thAccessDegraded

CpqDaLogDrvStatus.15

Minor (3)

Advertising