Product overview, Product description, Product features – HP Insight Management for Tivoli User Manual

Page 7: Prerequisites

Advertising
background image

Product overview 7


Product overview

Product description

HP Insight integration module for Netcool/OMNIbus is a comprehensive solution that provides
infrastructure management across a wide range of operating system platforms. This functionality

enables you to manage HP server and storage hardware, in addition to other enterprise resources,
from a common Netcool/OMNIbus environment. Supported operating platforms for the host include

HP-UX, Sun Solaris, Windows Server® 2000, Windows Server® 2003, Windows Server® 2008,
and Linux. Supported operating platforms for managed systems include HP-UX, Sun Solaris, IBM AIX,
Windows Server® 2000, Windows Server® 2003, Windows Server® 2008, Linux, HP Tru64

UNIX®, and HP OpenVMS.
The HP Insight integration module for Netcool/OMNIbus provides definitions for over 2550

individual notifications defined in its rules file and to correlate nearly 785 SNMP events. These
definitions and rules integrate closely with the Netcool/OMNIbus application using the Mttrapd

probe, enabling HP SNMP events and Fibre Channel Management SNMP events to be identified,
processed, translated, and appear on the Event List.

Product features

Integrates into Netcool/OMNIbus v7.2.1 on HP-UX, AIX, Solaris, Linux and Windows®

Contains over 2550 SNMP trap definitions for HP ProLiant servers and HP storage platforms

Translates and displays SNMP events from all Managed Nodes and Endpoints that have HP

Insight Management Agents installed on Microsoft® Windows NT®, Windows® 2000,

Windows® 2003, Windows® 2008, NetWare, Solaris, Linux, Tru64 UNIX®, and Open VMS

Provides predefined rules that identify and correlate nearly 785 HP ProLiant and Fibre Channel

Management SNMP events

Provides support up to HP Insight Management Agents version 8.60 for ProLiant servers

Prerequisites

Before uploading the rules and lookup files for Netcool/OMNIbus, be sure that you meet these
additional installation requirements:

To access the complete functionality provided with Netcool/OMNIbus, the target Netcool

environment must be fully configured and operational before installation.

The Probes, Object Server, and Desktop tools are the only required Netcool/OMNIbus

components.

Verify that the correct levels of the IBM Netcool/OMNIbus and related patches have been

installed.

SNMP services must be installed and configured on all HP managed systems.

The Mttrapd probe must be installed and running.

Advertising