HP Insight Management for Tivoli User Manual

Page 61

Advertising
background image

Appendix B: HP SNMP events 61


Trap types

Rules file

Description

Netcool

severity

cpqRackPowerSupplyFailed
(22013)

22013

This event occurs when the
power supply status is set to
Failed.

Critical (5)

cpqRackPowerSupplyDegraded

(22014)

22014

This event occurs when the

power supply status is set to
Degraded.

Major (4)

cpqRackPowerSupplyOk (22015) 22015

This event occurs when the

power supply status is set to OK.

Clear (0)

cpqRackPowerSupplyRemoved

(22016)

22016

This event occurs when the

power supply is removed.

Minor (3)

cpqRackPowerSupplyInserted

(22017)

22017

This event occurs when the

power supply is inserted.

Clear (0)

cpqRackPowerSubsystemNotRedu

ndant (22018)

22018

This event occurs when the rack

power subsystem is no longer in
a redundant state.

Major (4)

cpqRackPowerSubsystemLineVolta
geProblem (22019)

This event occurs when the rack
power supply detected an input

line voltage problem.

CpqRackPowerSupplyInputLineSta

tus:noError

CpqRackPowerSuppl

yInputLineStatus.1

Clear (0)

CpqRackPowerSupplyInputLineSta

tus:lineOverVoltage

CpqRackPowerSuppl

yInputLineStatus.2

Major (4)

CpqRackPowerSupplyInputLineSta

tus:lineUnderVoltage

CpqRackPowerSuppl

yInputLineStatus.3

Major (4)

CpqRackPowerSupplyInputLineSta

tus:lineHit

CpqRackPowerSuppl

yInputLineStatus.4

Major (4)

CpqRackPowerSupplyInputLineSta

tus:brownout

CpqRackPowerSuppl

yInputLineStatus.5

Major (4)

CpqRackPowerSupplyInputLineSta

tus:linePowerLoss

CpqRackPowerSuppl

yInputLineStatus.6

Critical (5)

cpqRackPowerSubsystemOverloa
dCondition (22020)

22020

This event occurs when there is
a rack power subsystem

overload condition.

Major (4)

cpqRackPowerShedAutoShutdow

n (22021)

22021

This event occurs when the

server blade shuts down due to
lack of power.

Critical (5)

cpqRackServerPowerOnFailedNot

Redundant (22022)

22022

This event occurs when there is

not enough power to power on
the server blade and maintain

redundancy for the other blades
in the enclosure.

Major (4)

cpqRackServerPowerOnFailedNot
EnoughPower (22023)

22023

This event occurs when there is
not enough power to power on

the server blade.

Critical (5)

Advertising