SET ENCLOSURE NAME

Command:

SET ENCLOSURE NAME "<enclosure name>"

Description:

Changes the enclosure name.

The default enclosure name is the mid-plane serial number.

Access level/Bay level:

OA Administrator, OA Operator

Restrictions:

The <enclosure name> must be 1 to 32 characters long and includes all alphanumeric,
underscore (_), and dash (-) characters.

SET ENCLOSURE PART_NUMBER

Command:

SET ENCLOSURE PART_NUMBER "<part number>"

Description:

Sets the part number of the enclosure

Access level/Bay level:

OA Administrator

Restrictions:

Must be 10 characters in length and the first character must be a digit. Acceptable characters
are all alphanumeric and the dash (-).

SET ENCLOSURE PDU_TYPE

Command:

SET ENCLOSURE PDU_TYPE {1|2|3|4}

Description:

Sets the enclosure PDU type to:

1 = Single-phase

2 = Three-phase

3 = Three-phase, international

4 = DC Power Input Module

Access level/Bay level:

OA Administrator

Restrictions:

Only 1, 2, 3, 4 are valid PDU types.