HP XP P9500 Storage User Manual

Page 117

Advertising
background image

Description

Error code (SSB2)

The command was rejected because the specified mirror ID was invalid.

EB30

The specified Cnt Ac-J pair cannot execute the takeover because the specified Cnt Ac-J pair
belongs to the journal that dedicated Cnt Ac-J and Continuous Access Synchronous combination
(2DC configuration).

EB45

A delta resync pair cannot be created due to one of the following reasons.

EB48

P-VOL of the Cnt Ac-J pair is different from P-VOL of the Continuous Access Synchronous pair.

The serial number of the primary system that is recognized by P-VOL and S-VOL is different.

The command was rejected because the secondary system did not support the delta resync
function.

EB49

A pair cannot be created because the restore journal was not registered.

EB4C

A pair cannot be created because the master journal was not registered.

EB4D

The Cnt Ac-J pair cannot be created because the timer type of master journal and restore journal
is different.

EB4F

The command was rejected because the specified S-VOL was not mounted.

EB50

The command was rejected because PIN data existed in the specified S-VOL.

EB51

The command was rejected because the specified S-VOL cannot be accessed.

EB52

The command was rejected because the specified S-VOL is blocked.

EB53

The command was rejected because the specified P-VOL is used for the external volume which
is mapped for the online data migration.

EB54

The command was rejected because the specified S-VOL was online from the host.

EB57

The command was rejected because the specified journal volume or S-VOL was reserved or being
used in the storage system. Please check the status of the volume.

EB58

The command was rejected because the specified S-VOL was being migrated by Auto LUN.
Please check the status of the volume.

EB59

The command was rejected because the access attribute was set to the specified P-VOL or S-VOL
by the Data Retention.

EB5B

The command was rejected because an internal logical error occurred.

EB5C

The command was rejected because the state of S-VOL was not SMPL.

EB5E

The command was rejected because the program product of Cnt Ac-J was not installed in the
secondary system.

EB5F

The command was rejected by either of the following reasons:

EB60

The volume capacity of P-VOL was does not conform with the volume capacity of S-VOL.

Capacities of each volumes that are concatenated in LUSE on the primary site does not conform
with capacities of each volumes that are concatenated in LUSE on the secondary site.

The command was rejected because the path between the primary and the secondary systems
was not valid.

EB61

The command was rejected because the specified P-VOL was a command device.

EB62

The command was rejected because the restore journal was already linked with another journal.

EB63

The command was rejected because the desired capacity exceeded the charging capacity of
the program product.

EB64

The command was rejected because of the abnormal end which is related to the charging capacity
of the program product.

EB65

Troubleshooting with RAID Manager

117

Advertising