Actions, Battery – HP NonStop G-Series User Manual

Page 80

Advertising
background image

UNI Management Entity VPI

The User-Network interface (UNI) management entity virtual path
identifier (VPI).

Value: 0 through 255

Maximum Number of VCIs

The maximum number of Virtual Circuit IDs (VCIs) that can be
active for permanent virtual circuits.

Value: 32 through 3072

UNI Version

The version of the User-Network Interface (UNI) supported by this
ATM line.

Maximum Number of VPIs

The maximum number of virtual path identifiers (VPIs) for
permanent virtual circuits.

Value: 0 through 256

ATM Address Registered

The address that is registered for this ATM Line.

Device State

The state of the component as known to the operating system on the
server.

Values

Maximum Number of VCI Bits

The address width and the maximum number of Virtual Circuit ID
(VCI) bits that can be active.

Value: 0 through 16

UNI Management Entity VCI

The User-Network interface (UNI) management entity virtual
circuit identifier (VCI).

Value: 0 through 3071

Maximum Number of VPI Bits

The address width and the maximum number of Virtual Path ID
(VPI) bits that can be active.

Value: 0 through 8

Actions

None.

Battery

Attributes

Actions

The battery customer-replaceable unit (CRU), located in Nonstop S-series I/O enclosures, is an
assembly of 24 cells rated at 2.5 amp-hours per cell. The batteries are designed to handle occasional
power failures that might occur at typical computer sites. Each I/O enclosure contains two batteries.

Location in OSM Tree: System > Group > Module > Battery

Slot Location: In processor enclosures, battery CRUs are located in slots 23 and 28 (appearance
side).