Table row, Exercise mech, Wellness test – HP Optical Jukeboxes User Manual

Page 72: Clear soft log, Sets the soft error log to zero, Clear hard log, Sets the hard error log to zero, Plunge full spd, Plunge 1/2 spd, Used by service personnel only

Advertising
background image

3-32

Chapter 3

Operating the Jukebox

Running an Internal Test

EXERCISE MECH

Runs the VERTICAL TEST, TRANSLATE TEST,
FLIP TEST, MAGAZINE IO, DRIVE IO, and
MAILSLOT IO tests. Each test runs one time per test
loop.

WELLNESS TEST

Checks the general capability of the jukebox. Requires
one loaded disk. The drives, transport, and mailslot
must be empty.

Runs

INIT MECHANICS

and

EXERCISE MECHANICS

.

Each test runs one time per

test loop

.

CLEAR SOFT LOG

Sets the soft error log to zero.

CLEAR HARD
LOG

Sets the hard error log to zero.

PLUNGE FULL
SPD

Allows the disk transport mechanics to run at full
speed. This setting should always be used in normal
jukebox operation.

PLUNGE 1/2 SPD

Used by service personnel only.

Allows the disk

transport mechanics to run at half speed

.

PLUNGE 1/4 SPD

Used by service personnel only.

Allows the disk

transport mechanics to run at quarter speed.

STARWARS

The display shows 0 0 0.

Each “0" indicates one of the paths that the disk
transport mechanism follows in front of each stack of
optical disks. If the path is clear, a “0” displays; if the
path is blocked (because of an optical disk that is not
inserted fully into its storage slot for example), an “*”
will be displayed. This display is automatically updated
if the status changes.

Test Name

Description