Host name, Hp insight control power management – HP Systems Insight Manager User Manual

Page 186

Advertising
background image

3.

In the Name field, enter a name for the new toolbox.

4.

In the Description field, enter a description for the new toolbox.

5.

Select Toolbox

is enabled.

6.

Under Show Tools in Category, select Configuration Tool from the dropdown list.

7.

Select Delete Events and Clear Events, and move them to the Toolbox contents window.

8.

Click OK

Next, create an authorization on the systems that you want to enable the user to clear or delete
events.
1.

Select Options

SecurityUsers and Authorizations.

2.

Select the Authorizations tab, and click New.

3.

In the Select field, select the users or user groups to which to assign the toolbox.

4.

In the Select Toolbox(es) section, select the toolbox you created in step 2.

5.

In the Select Systems section, select the systems that you want this toolbox to apply.

6.

Click OK.

Create an event collection, and run the tool through the menus.
-------------------------------------------------------------
When event types are dynamically added, you must manually refresh any event collections that
are currently displayed

Host name

When installing HP SIM, CMS host names that exceed 15 characters are truncated, and the
truncated name must be used to complete the installation. After the install, two administrator accounts
are created. One account includes the original hostname\administrator and the other
account includes the truncated hostname\administrator.
Solution: To sign in, you must use the original host name in the Domain field on the Sign in page.

HP Insight Control power management

To manage ProLiant blades running ESX 3.0.x or 3.5 with the virtual ID option turned on, the HP
ProLiant SNMP Agent for ESX package must be installed. You can use the Configure or Repair
Agents feature in HP SIM to install the package. If you have already discovered ESX classic servers
before the ProLiant SNMP Agent is installed, you must delete these systems, install the ProLiant
SNMP agent on them, and re-discover them.
-------------------------------------------------------------
While restoring the Onboard Administrator configuration, initially the following message appears
if the network communication to Onboard Administrator is slow. Save/Restore operation
is taking more than the expected time. Please wait while the save/restore
operation completes

. If the restore operation exceeds 4 minutes on Onboard Administrator,

a message appears stating that the save/restore operation could not be completed, however, the
operation does complete.
-------------------------------------------------------------
When an Onboard Administrator is discovered, the enclosure that it resides in is created. If this
enclosure is daisy chained to other c-class enclosures, then these enclosures are also created. By
default, daisy chained enclosures are displayed as c7000 enclosure models. As a result, when
c7000 and c3000 enclosures are daisy chained, and the Onboard Administrator is discovered,
the c3000 Tower Model enclosure is displayed as a c7000 enclosure. To ensure that the daisy
chained enclosures are displayed accurately, you must discover the Onboard Administrator on
each of these enclosures.
-------------------------------------------------------------
To correctly identify the xw25p Blade Workstation, you must install Insight Management Agent
7.4.
-------------------------------------------------------------

186 Troubleshooting