Cooling and temperature, System information – HP Insight Management Agents User Manual

Page 107

Advertising
background image

NVRAM Invalid

Calibration Table Invalid

If the power supply is absent, the status is "Not Applicable"

Used Capacity (%)—Represents the current power supply capacity which is a percentage of
its maximum capacity.

Used Capacity (W)—Represents the current power supply capacity in watts.

Max Capacity—Represents the maximum capacity of the power supply in watts.

Model—Represents the power supply model name.

Voltage—Represents the Input Main Voltage of the power supply in volts.

Redundancy State—Represents the redundancy state of the power supply. The following
values are possible:

Redundant

Not Redundant

Unknown

Hot Pluggable—Represents if the power supply is capable of being removed and/or inserted
while the system is in an operational state. The following values are possible:

Hot Plug

Non-hot-plug

Unknown

Power Meter Information—Current power meter reading value shows the most recent power
reading.

Cooling and temperature

This section displays details on the device environment. The following information is available.

System Information

Degraded Action—Allows you to designate what action is taken when the device environment
becomes degraded. The options are:

Continue—The health or wellness driver signals the operating system to continue functioning
in situations where the temperature is too high or too low. In more serious temperature
situations, the device shuts down automatically.

Shut Down—The health or wellness driver signals the operating system to shut down in
situations where the temperature is too high or too low. In more serious temperature
situations, the device shuts down automatically.

Unknown—You may need to upgrade your driver software or Server Agents or the Server
Agent cannot determine the status of the device.

Overall Thermal and Fan Status—Displays the overall condition of the system's thermal
environment. The options are:

Failed—If the thermal temperature status or thermal CPU fan status or thermal System fan
status is failed.

Degraded—If the status is not failed and thermal temperature status or thermal CPU fan
status or thermal System fan status is degraded.

Sub-system Classification 107

Advertising