Installation instructions, Warning, Connecting dryer using 3-wire connection – GE GTDX185EDCC User Manual

Page 3: Exhaust information, Exhaust system check list, Never leave the cover off of the terminal block

Advertising
background image

Installation Instructions



CONNECTING DRYER USING 3-WIRE
CONNECTION

3-wire Connection
Not for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.
NOT for use on recreational vehicles.
NOT for use in areas where local codes prohibit grounding
through the neutral conduction.

1. 7XUQ RȺ WKH FLUFXLW EUHDNHU V   DPS  RU UHPRYH WKH

dryer’s circuit fuse at the electrical box.

2. Be sure the dryer cord is unplugged from the wall.
 5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHUEDFN

4. ,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG

entry hole. Bring power cord through strain relief.

5. Connect power cord as follows:

A. Connect the 2 hot lines to the outer screws of

the terminal block (marked L1 and L2).

B. Connect the neutral (white) line to the center of

the terminal block (marked N).

6. Be sure ground strap is connected to neutral (center)

terminal of block and to green ground screw on cabinet
UHDU7LJKWHQDOOWHUPLQDOEORFNVFUHZV  VHFXUHO\

7. Properly secure power cord to strain relief.
8. 5HLQVWDOOWKHFRYHU

3

EXHAUST INFORMATION

WARNING -

IN CANADA AND IN THE

UNITED STATES, THE REQUIRED EXHAUST
DUCT DIAMETER IS 4 IN (102mm). DO NOT
USE DUCT LONGER THAN SPECIFIED IN THE
EXHAUST LENGTH TABLE.

8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO

• Increase the drying times and the energy cost.
‡5HGXFHWKHGU\HUOLIH
‡$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG

The correct exhaust installation is YOUR
RESPONSIBILITY. Problems due to incorrect installation
are not covered by the warranty.
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLOWUDQVLWLRQ

duct and replace with UL listed transition duct.
The MAXIMUM ALLOWABLE duct length and number of
bends of the exhaust system depends upon the type of
duct, number of turns, the type of exhaust hood (wall cap),
and all conditions noted below. The maximum duct length
for rigid metal duct is shown in the table below.

EXHAUST LENGTH

4" DIA.

4"

4" DIA.

4" DIA.

2-1/2"

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

No. of 90º

Elb ows

Rigid

Metal

Rigid

Metal

90 F eet
60 F eet
45 F eet
35 F eet
25 F eet

0
1
2
3
4

60 F eet
45 F eet
35 F eet
25 F eet
15 F eet

Use only for sho rt

run installations

EXHAUST SYSTEM CHECK LIST

HOOD OR WALL CAP

• Terminate in a manner to prevent back drafts or entry of

birds or other wildlife.

• Termination should present minimal resistance to the

H[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFH

to prevent clogging.

Never install a screen in or over the exhaust duct. This could

cause lint build up.

• Wall caps must be installed at least 12 in. above ground

level or any other obstruction with the opening pointed
down.

SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft.
of straight duct, including distance between last turn and
exhaust hood.
TURNS OTHER THAN 90º
• One turn of 45º or less may be ignored.
• Two 45º turns should be treated as one 90º turn.
• Each turn over 45º should be treated as one 90º turn.

• For every extra 90° elbow, reduce the allowable vent system

length by 10 ft.

• Two 45° elbows will be treated like one 90° elbow.
• For the side exhaust installations, add one 90° elbow to the

chart.

• The total vent system length includes all the straight portions

and elbows of the system (transition duct included).

WARNING:

NEVER LEAVE THE

COVER OFF OF THE TERMINAL BLOCK.

Screws

(2)

Hot

Wire

µ8/

5HFRJQL]HG

6WUDLQ5HOLHI

$:*PLQLPXPFRSSHUFRQGXFWRUVRU9$SRZHUVXSSO\

cord kit marked for use with dryers and provided with closed loop or

spade terminals with upturned ends (not supplied).

Fuse

Hot

Wire

Neutral

(white)

Strain
5HOLHI

Bracket

Cover

Screw

If required, by local code, install external ground (not provided) to

grounded metal, cold water pipe, or other established ground determined

by a qualified electrician.

Green Ground Screw

& Ground Strap

Advertising